formcure_uv
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| formcure_uv [2020/07/09 02:12] – [Reference Documentation] furst | formcure_uv [2020/10/08 17:00] (current) – [Operating Procedures] furst | ||
|---|---|---|---|
| Line 3: | Line 3: | ||
| ^ | ^ | ||
| | {{ : | | {{ : | ||
| - | | **Tool Type: | + | | **Tool Type: |
| - | | **Location: | + | | **Location: |
| Line 12: | Line 12: | ||
| | bothman@cnsi.ucsb.edu | | bothman@cnsi.ucsb.edu | ||
| - | | **Description: | + | | **Description: |
| - | | **Manufacturer: | + | | **Manufacturer: |
| ---- | ---- | ||
| Line 19: | Line 19: | ||
| ===== About ===== | ===== About ===== | ||
| - | Insert Text Here! | + | Some FormLabs Resins used in the Form 2 3D printer can benefit from post process curing. Each resin has a specific hardening curve which can be found within the reference material which will indicate the ideal time and temperature to be set on the FormCure. |
| ---- | ---- | ||
| ===== Detailed Specifications ===== | ===== Detailed Specifications ===== | ||
| + | * Max cure temp: 80 degrees C | ||
| + | * Light: 39W total drawn by 13 405 nm LEDs | ||
| - | Insert Text Here! | ||
| ---- | ---- | ||
| Line 31: | Line 32: | ||
| ===== Safety Concerns ===== | ===== Safety Concerns ===== | ||
| - | Insert Text Here! | + | * Allow at least half an hour for IPA to evaporate before placing part in Form Cure |
| + | * Allow time for the Form Cure to cool off before removing parts | ||
| + | * Do not operate form cure with lid open | ||
| ---- | ---- | ||
| Line 37: | Line 40: | ||
| ===== Operating Procedures ===== | ===== Operating Procedures ===== | ||
| - | Insert Text Here! | + | - Any part to be cured needs to be washed in the FormWash with IPA BEFORE being placed in the form cure. Supports can be removed before or after curing process. |
| + | - Wait 30 minutes after washing to allow all remaining IPA to evaporate | ||
| + | - Check the reference material for selected resin to determine ideal time and temperature for curing | ||
| + | - Use the dial on the front of the FormCure to set time and temperature | ||
| + | - Place part within the FormCure-> | ||
| - | ---- | + | ----- |
| ===== Reference Documentation ===== | ===== Reference Documentation ===== | ||
| Line 53: | Line 60: | ||
| ===== Training Documentation ===== | ===== Training Documentation ===== | ||
| - | + | [[form2sop|Form 2 Training SOP]] | |
| - | Insert Text Here! | + | |
| ---- | ---- | ||
formcure_uv.1594260779.txt.gz · Last modified: 2020/07/09 02:12 by furst