| + | * Max cure temp: 80 degrees C | ||
| + | * Light: 39W total drawn by 13 405 nm LEDs | ||
| - | Insert Text Here! | ||
| ---- | ---- | ||
| Line 31: | Line 32: | ||
| ===== Safety Concerns ===== | ===== Safety Concerns ===== | ||
| - | Insert Text Here! | + | * Allow at least half an hour for IPA to evaporate before placing part in Form Cure |
| + | * Allow time for the Form Cure to cool off before removing parts | ||
| + | * Do not operate form cure with lid open | ||
| ---- | ---- | ||
| Line 37: | Line 40: | ||
| ===== Operating Procedures ===== | ===== Operating Procedures ===== | ||
| - | Insert Text Here! | + | - Any part to be cured needs to be washed in the FormWash with IPA BEFORE being placed in the form cure. Supports can be removed before or after curing process. |
| + | - Wait 30 minutes after washing to allow all remaining IPA to evaporate | ||
| + | - Check the reference material for selected resin to determine ideal time and temperature for curing | ||
| + | - Use the dial on the front of the FormCure to set time and temperature | ||
| + | - Place part within the FormCure-> | ||
| - | ---- | + | ----- |
| ===== Reference Documentation ===== | ===== Reference Documentation ===== | ||
| Line 53: | Line 60: | ||
| ===== Training Documentation ===== | ===== Training Documentation ===== | ||
| - | + | [[form2sop|Form 2 Training SOP]] | |
| - | Insert Text Here! | + | |
| ---- | ---- | ||