keyence_microscope
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| keyence_microscope [2020/03/12 18:24] – [Documentation] martinez | keyence_microscope [2020/11/12 18:34] (current) – [Safety Concerns] furst | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Keyence VHX-5000 Microscope ====== | ====== Keyence VHX-5000 Microscope ====== | ||
| - | The following is a sample image that can be inserted by clicking on the small picture frame icon in the edit bar. | + | |
| ^ | ^ | ||
| - | | | + | | {{ : |
| - | | **Tool Type: | + | | **Tool Type: |
| - | | **Location: | + | | **Location: |
| | **Supervisor** | | **Supervisor** | ||
| - | | David Bothman | + | | David Bothman |
| - | | (805) 893-4125 | + | | (805) 893-4125 |
| - | | bothman@cnsi.ucsb.edu | + | | bothman@cnsi.ucsb.edu |
| - | | **Description: | + | | **Description: |
| - | | **Manufacturer: | + | | **Manufacturer: |
| ---- | ---- | ||
| Line 21: | Line 21: | ||
| ===== About ===== | ===== About ===== | ||
| - | Insert Text Here! | + | The Keyence microscope is a semi computer controlled microscope that is capable of taking precision measurements from large depth of field images under high magnification. This microscope features both backlighting and top lighting, and has a computer controlled movable stage which can be used to pan across the object you are viewing. This microscope has a motorized objective which can be used to image parts with a large depth of field to create a single in focus image with depth mapping data. The motorized stage also allows for the stitching of several images to create larger high magnification pictures. |
| + | |||
| + | ---- | ||
| + | |||
| + | ===== Training Documentation ===== | ||
| + | [[Keyence SOP]] | ||
| ---- | ---- | ||
| ===== Detailed Specifications ===== | ===== Detailed Specifications ===== | ||
| + | * 17 mm/s Z travel | ||
| + | * Objective rotation up to 90 degree angle from normal stage axis | ||
| + | * Image stitching up to 20,000 x 20,000 pixels | ||
| + | * Optical zoom from o to 1000x | ||
| + | * 50 FPS max framerate | ||
| - | Insert Text Here! | ||
| ---- | ---- | ||
| ===== Safety Concerns ===== | ===== Safety Concerns ===== | ||
| + | * Do not leave lighting elements on | ||
| + | * Do not crash the objectives | ||
| + | * If replacing the bulb in the MI-150 wear gloves to avoid getting oil on the halogen lamp bulb | ||
| - | Insert Text Here! | ||
| ---- | ---- | ||
| - | ===== Operating Procedures ===== | ||
| - | Insert Text Here! | + | ===== Reference Documentation ===== |
| + | {{: | ||
| - | ---- | + | {{: |
| - | ===== Reference Documentation ===== | + | {{: |
| - | Insert Text Here! | + | {{: |
| - | ===== Training Documentation ===== | + | {{: |
| + | |||
| + | {{: | ||
| + | |||
| + | {{: | ||
| + | |||
| + | ----- | ||
| - | Insert Text Here! | ||
| - | ---- | ||
keyence_microscope.1584037440.txt.gz · Last modified: by martinez