shimadzu_nexera_analytical_hplc [2024/10/16 19:48] – created mbatesshimadzu_nexera_analytical_hplc [2026/06/02 20:29] (current) – saejinoh
Line 8: Line 8:
  
 |  **Principal Scientist**        |  **Training and Operations Lead**  |      |  **Principal Scientist**        |  **Training and Operations Lead**  |     
-|  Morgan Bates         |  Zachary Nett  | +|  David Fisher         |  Zachary Nett  | 
-|  morganbates@ucsb.edu         |  zjnett@ucsb.edu  |+|  dfisher@ucsb.edu         |  zjnett@ucsb.edu  |
  
 ---- ----
Line 15: Line 15:
 ===== About ===== ===== About =====
  
-The Genevac EZ-2 4.0 Elite is a high-performance parallel evaporator system designed to efficiently remove solvents from samples through evaporation. It uses advanced vacuum and centrifugal technology to evaporate a wide range of solvents, including volatile organic compounds and aqueous solutions, without overheating or degrading sensitive samples. The EZ-2 Elite features a dry scroll pump and is optimized for removal of even the highest boiling point solvents (> 165 °C), such as DMSO and NMP.+The Shimadzu Nexera Analytical HPLC system enables the identification and quantification of complex mixtures, while also supporting method development for sample purification on both preparative and semi-preparative scales. Equipped with a 6-way switch valve, the system streamlines the selection between four distinct columns, each offering unique surface chemistry and retention properties. These include C18 columns with 100 and 300 Å pore sizes, a C4 column, and a HILIC column. The system's design also allows for easy eluent interchanges, ensuring flexible adaptation to various purification and characterization requirements. Additionally, it features a dedicated PDA and a single quad LCMS-2050 mass spectrometer, which is capable of both ESI and APCI ionization and covers a mass range of 10-2000 m/z.
  
 ---- ----
  
  
-===== Solvent Guidelines and Sample Holder Options =====+===== Reference Documentation =====
  
-**Solvent Compatibility** \\ +{{ :analytical_hplc_manual.pdf | NSF BioPACIFIC MIP Analytical HPLC-MS User Manual}}
- +
-SP Genevac evaporators are robust systems designed to be resistant to the most common solvents and acids used within the chemistry laboratory, including TFA and HCl. **However, the Genevac is not compatible with the following:**\\ +
- +
-• Carbon disulfide\\ +
-• Diethyl ether\\ +
-• 1,2-Dimethoxyethane\\ +
-• 2-Ethoxyethanol\\ +
-• Hydrogen cyanide\\ +
-• Pentane\\ +
-• Triethylsilane\\ +
- +
-**Sample formats** +
- +
-Sample holders for the following formats are available:\\ +
- +
-• **Vials:** 40, 30, 20, and 8-mL sizes \\ +
-• **Test tubes:** 16, 18, and 25-mm diameter and up to 150 mm length \\ +
-• **Centrifuge tubes:** 50-mL size+
  
 ---- ----
- 
- 
  
  