Line 26: Line 26:
   * **Rule of thumb:** Best to do in the mornings or weekends.    * **Rule of thumb:** Best to do in the mornings or weekends. 
  
-5. //Check and replenish hazardous waste labels// +5. //Check and replenish hazardous waste/waste labels// 
 +  - Empty solvent bottles should be rinsed, have their labels removed, and have a waste solvent label pre tagged. 
 +  - If waste bin is HALF full, [[https://hazwaste.ehs.ucsb.edu/HazWasteRequestDetail/93286417/244431_1-top|contact]] EH&S to schedule a waste pickup 
 6. //Check sharps containers// 6. //Check sharps containers//
   * If full, tape off the top and place in the hazardous waste bin.   * If full, tape off the top and place in the hazardous waste bin.
Line 111: Line 112:
 ** **
  
-I) Check gloves: extra boxes are in microfluidics lab, write down what is taken on clipboard near the door.+I) Check gloves: extra boxes are in microfluidics lab, write down what is taken on clipboard on the fume hood nearest to the exit.
  
 2) Check paper towels/WypAll: there is a dispenser above every sink and the key should already be in the dispenser. 2) Check paper towels/WypAll: there is a dispenser above every sink and the key should already be in the dispenser.
Line 143: Line 144:
 16) Charge the camera battery: battery door is on bottom of camera and there is a wall charger in the fume hood. 16) Charge the camera battery: battery door is on bottom of camera and there is a wall charger in the fume hood.
  
-17) Calibrate the scanner: follow the instructions on the computer +17) Calibrate the scanner:  
 +I) Go into the Einscan software on the desktop, then choose Einscan sp. 
 +II) Choose calibrate in the main interface. 
 +III) Place the Calibration stand on the turn-wheel and orient the calibration board (using the reference dots) on the stand as shown in the image on the software. 
 +IV) Press snap. Once complete, re-orient the board and snap again until the process is finished. 
 +   Note: The board and the stand can be found in the scanner fume hood.
 18) Turn off camera box light: the power button is on the side 18) Turn off camera box light: the power button is on the side
  
Line 167: Line 172:
 25) When replacing the liners in the 3D printer cleaning fume hood, use the stock in the cabinet located to the lower left of the hood. 25) When replacing the liners in the 3D printer cleaning fume hood, use the stock in the cabinet located to the lower left of the hood.
  
-26) Fill out the IPA in the resin cleaner to the halfway point of the indicator.+26) Fill out the IPA in the resin cleaner to the halfway point of the indicator lines.
 Measure the specific gravity of the IPA in the cleaner. If the O-ring on the measuring device sits above the large flaps, replace the IPA. Measure the specific gravity of the IPA in the cleaner. If the O-ring on the measuring device sits above the large flaps, replace the IPA.
 Reminder: Check the IPA level in the squirt bottles regularly. Reminder: Check the IPA level in the squirt bottles regularly.
Line 174: Line 179:
    
 28) Stratasys maintenance: 28) Stratasys maintenance:
-a) Check the filament level, replace it with stock from the shelves in the corridor if necessary. +a) Check the filament level, replace it with stock from the shelves in the corridor if necessary. (more details to be posted) 
-b) To vacuum the printer, go to settings and bring the gantry up; preferably use gloves.+b) To vacuum the print platform, go to settings and bring the gantry up; preferably use gloves.
    
 29) Miicraft maintenance: Remove the resin cover and mix the resin with a disposable pipette (found on the big, white box across the room) until the solution is homogeneous. Return the cover to protect from dust. 29) Miicraft maintenance: Remove the resin cover and mix the resin with a disposable pipette (found on the big, white box across the room) until the solution is homogeneous. Return the cover to protect from dust.
Line 183: Line 188:
 Note: This device is particularly dangerous. Wear gloves, coat, and face shield when opening the door. Ask Daniel or Mr. Bothman for detailed instructions. Note: This device is particularly dangerous. Wear gloves, coat, and face shield when opening the door. Ask Daniel or Mr. Bothman for detailed instructions.
 Note: The alarm may sound if the container is lowered too quickly. Silence the alarm with the button that is indicated with a warning light but do so only if you are certain that this was the cause of the alarm. Note: The alarm may sound if the container is lowered too quickly. Silence the alarm with the button that is indicated with a warning light but do so only if you are certain that this was the cause of the alarm.
 +-----
 +==== Workshop Wizard Wiki Guide ====
 +PLEASE ONLY EDIT IF YOU CAN IMPROVE A PAGE. 
 +{{:wiki:microfluidics_and_innovation_workshop_wiki_guide.pdf|}}
 +
 +
  