=====EinScan-SP Training SOP===== | =====EinScan-SP Training SOP===== | ||
- | ====Tool Name and Location==== | + | Last edited: Furst (8/28/20) |
- | The SHINING3D | + | |
+ | Instructor: | ||
+ | |||
+ | Date: | ||
+ | |||
+ | {| style="" | ||
+ | |+ Attendees: | ||
+ | ! | ||
+ | |||
+ | ! | ||
+ | Name | ||
+ | ! | ||
+ | Group or Company | ||
+ | ! | ||
+ | Signature | ||
+ | |- | ||
+ | |1 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |2 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |3 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |4 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |5 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |6 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |} | ||
+ | |||
+ | ----- | ||
+ | |||
+ | ====Overview: | ||
+ | This training provides an introduction to using the EinScan including: | ||
+ | * Setting up and calibrating the scanner | ||
+ | * Optimal conditions and techniques for scanning particulate parts | ||
+ | * Using the EinScan Turntable | ||
+ | * Fixing/ | ||
+ | |||
+ | ====Location:==== | ||
+ | the EinScan is located in fume hood #1 in the Innovations Workshop | ||
====Safety==== | ====Safety==== | ||
**Machine Limitations: | **Machine Limitations: | ||
* The turntable has a maximum weight limit of 5kg (~11lbs). Exceeding this weight could damage the machine and its internal components. | * The turntable has a maximum weight limit of 5kg (~11lbs). Exceeding this weight could damage the machine and its internal components. | ||
- | **Environmental: | + | **Environmental: |
* Keep the scanner in a well ventilated area. Keep flammables, corrosive agents, and liquids away from the scanner. Failing to do so will damage the machine and its internal components. | * Keep the scanner in a well ventilated area. Keep flammables, corrosive agents, and liquids away from the scanner. Failing to do so will damage the machine and its internal components. | ||
**Physical: | **Physical: | ||
* The projector emits a bright light. Avoid looking directly into the light source to prevent eye injury. | * The projector emits a bright light. Avoid looking directly into the light source to prevent eye injury. | ||
- | ====Training==== | + | ====Training==== |
- | **training | + | **Training |
Users must attend the in-person training session and should consult the Safe Operating Procedure and EinScan-SP Manual (both found on the Innovation Workshop GauchoSpace page). | Users must attend the in-person training session and should consult the Safe Operating Procedure and EinScan-SP Manual (both found on the Innovation Workshop GauchoSpace page). | ||
+ | |||
**Training Outline** | **Training Outline** | ||
- Overview of the scanner and the system setup | - Overview of the scanner and the system setup | ||
Line 40: | Line 99: | ||
====Safe Operation of this Tool==== | ====Safe Operation of this Tool==== | ||
**Before Using the Scanner:** | **Before Using the Scanner:** | ||
+ | |||
Make sure that the object: | Make sure that the object: | ||
* Is larger than 30x30x30mm (1.2x1.2x1.2in) | * Is larger than 30x30x30mm (1.2x1.2x1.2in) | ||
Line 55: | Line 115: | ||
- Adjust __Brightness slider__ {{: | - Adjust __Brightness slider__ {{: | ||
- | **Scanning With the Turntable: | + | **Scanning With the Turntable: |
{{: | {{: | ||
- Check the __Use Turntable__ box and specify the number of increments (8-180 steps). The __Align Mode__ menu will appear. | - Check the __Use Turntable__ box and specify the number of increments (8-180 steps). The __Align Mode__ menu will appear. | ||
Line 126: | Line 186: | ||
----- | ----- | ||
- | ====Accident Response: | ||
====References==== | ====References==== | ||
**Manuals: | **Manuals: | ||
Line 158: | Line 217: | ||
{{: | {{: | ||
* The software will then prompt you to rotate the calibration board to match Orientation C. Carefully lift and rotate the calibration board without moving the stand. | * The software will then prompt you to rotate the calibration board to match Orientation C. Carefully lift and rotate the calibration board without moving the stand. | ||
- | * When properly oriented, click Snap {{: | + | * When properly oriented, click Snap {{: |
| | ||
After completing the scan of Orientation C, the software will automatically start the calibration process. A progress bar will display as the software calibrates. It will automatically return to the “Choose Working Mode” menu when the calibration is complete. \\ | After completing the scan of Orientation C, the software will automatically start the calibration process. A progress bar will display as the software calibrates. It will automatically return to the “Choose Working Mode” menu when the calibration is complete. \\ | ||
Remove the calibration board from the stand and place in the protective drawstring bag. Remove the stand from the turntable and proceed with scanning. | Remove the calibration board from the stand and place in the protective drawstring bag. Remove the stand from the turntable and proceed with scanning. | ||
- | + | ----- | |
+ | |||
+ | | ||
+ | Tool Lead: \\ | ||
+ | Contact: andrewfurst@ucsb.edu | ||
+ | ====Safety Concern==== | ||
+ | * Lab coat and gloves must me used when handling resin | ||
+ | * Anything with uncured resin must be transported within a container to avoid spilling | ||
+ | |||
+ | ====Safe Operation Procedures Review==== | ||
+ | - Create a new project and designate file location | ||
+ | - Select desired texture mode (texture uses color data whereas non texture takes less time) | ||
+ | - Adjust brightness slider to properly expose image | ||
+ | - Select desired scanning mode (turntable or tripod are standard) | ||
+ | - Start Scan | ||
+ | - After scan completion using shift + left click to remove extraneous data | ||
+ | - Correct any misalignment using the align and shift + left click to select coincident points | ||
+ | ====Post Processing and exporting==== | ||
+ | - Select mesh to convert to mesh body | ||
+ | - Select watertight to create closed object or unwatertight to edit object file | ||
+ | - Select desired simplification ratio (to reduce processor stress) and file type (.STL, .OBJ, .PLY, .3MF, or .ASC) | ||
+ | |||
+ | ====Maintenance==== | ||
+ | * Calibration should take place once a week or before a scan for optimal accuracy | ||
+ | * Scanner and turntable should be wiped down frequently | ||
+ | * Computer should be restarted periodically and plugged in | ||