einscantrainginsop
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
einscantrainginsop [2020/09/01 18:06] – [Safety] furst | einscantrainginsop [2020/09/04 18:13] (current) – furst | ||
---|---|---|---|
Line 67: | Line 67: | ||
**Physical: | **Physical: | ||
* The projector emits a bright light. Avoid looking directly into the light source to prevent eye injury. | * The projector emits a bright light. Avoid looking directly into the light source to prevent eye injury. | ||
- | ====Training==== | + | ====Training==== |
**Training requirements: | **Training requirements: | ||
Users must attend the in-person training session and should consult the Safe Operating Procedure and EinScan-SP Manual (both found on the Innovation Workshop GauchoSpace page). | Users must attend the in-person training session and should consult the Safe Operating Procedure and EinScan-SP Manual (both found on the Innovation Workshop GauchoSpace page). | ||
+ | |||
**Training Outline** | **Training Outline** | ||
- Overview of the scanner and the system setup | - Overview of the scanner and the system setup | ||
Line 98: | Line 99: | ||
====Safe Operation of this Tool==== | ====Safe Operation of this Tool==== | ||
**Before Using the Scanner:** | **Before Using the Scanner:** | ||
+ | |||
Make sure that the object: | Make sure that the object: | ||
* Is larger than 30x30x30mm (1.2x1.2x1.2in) | * Is larger than 30x30x30mm (1.2x1.2x1.2in) | ||
Line 113: | Line 115: | ||
- Adjust __Brightness slider__ {{: | - Adjust __Brightness slider__ {{: | ||
- | **Scanning With the Turntable: | + | **Scanning With the Turntable: |
{{: | {{: | ||
- Check the __Use Turntable__ box and specify the number of increments (8-180 steps). The __Align Mode__ menu will appear. | - Check the __Use Turntable__ box and specify the number of increments (8-180 steps). The __Align Mode__ menu will appear. | ||
Line 220: | Line 222: | ||
Remove the calibration board from the stand and place in the protective drawstring bag. Remove the stand from the turntable and proceed with scanning. | Remove the calibration board from the stand and place in the protective drawstring bag. Remove the stand from the turntable and proceed with scanning. | ||
- | + | ----- | |
+ | |||
+ | | ||
+ | Tool Lead: \\ | ||
+ | Contact: andrewfurst@ucsb.edu | ||
+ | ====Safety Concern==== | ||
+ | * Lab coat and gloves must me used when handling resin | ||
+ | * Anything with uncured resin must be transported within a container to avoid spilling | ||
+ | |||
+ | ====Safe Operation Procedures Review==== | ||
+ | - Create a new project and designate file location | ||
+ | - Select desired texture mode (texture uses color data whereas non texture takes less time) | ||
+ | - Adjust brightness slider to properly expose image | ||
+ | - Select desired scanning mode (turntable or tripod are standard) | ||
+ | - Start Scan | ||
+ | - After scan completion using shift + left click to remove extraneous data | ||
+ | - Correct any misalignment using the align and shift + left click to select coincident points | ||
+ | ====Post Processing and exporting==== | ||
+ | - Select mesh to convert to mesh body | ||
+ | - Select watertight to create closed object or unwatertight to edit object file | ||
+ | - Select desired simplification ratio (to reduce processor stress) and file type (.STL, .OBJ, .PLY, .3MF, or .ASC) | ||
+ | |||
+ | ====Maintenance==== | ||
+ | * Calibration should take place once a week or before a scan for optimal accuracy | ||
+ | * Scanner and turntable should be wiped down frequently | ||
+ | * Computer should be restarted periodically and plugged in | ||
einscantrainginsop.1598983568.txt.gz · Last modified: 2020/09/01 18:06 by furst