====== Keyence VHX-5000 Microscope ====== | ====== Keyence VHX-5000 Microscope ====== | ||
- | The following is a sample image that can be inserted by clicking on the small picture frame icon in the edit bar. | + | |
^ | ^ | ||
| {{ : | | {{ : | ||
- | | **Tool Type: | + | | **Tool Type: |
- | | **Location: | + | | **Location: |
Line 14: | Line 14: | ||
| bothman@cnsi.ucsb.edu | | bothman@cnsi.ucsb.edu | ||
- | | **Description: | + | | **Description: |
- | | **Manufacturer: | + | | **Manufacturer: |
---- | ---- | ||
Line 21: | Line 21: | ||
===== About ===== | ===== About ===== | ||
- | Insert Text Here! | + | The Keyence microscope is a semi computer controlled microscope that is capable of taking precision measurements from large depth of field images under high magnification. This microscope features both backlighting and top lighting, and has a computer controlled movable stage which can be used to pan across the object you are viewing. This microscope has a motorized objective which can be used to image parts with a large depth of field to create a single in focus image with depth mapping data. The motorized stage also allows for the stitching of several images to create larger high magnification pictures. |
---- | ---- | ||
- | ===== Detailed Specifications | + | ===== Training Documentation |
- | + | [[Keyence SOP]] | |
- | Insert Text Here! | + | |
---- | ---- | ||
- | ===== Safety Concerns | + | ===== Detailed Specifications |
+ | * 17 mm/s Z travel | ||
+ | * Objective rotation up to 90 degree angle from normal stage axis | ||
+ | * Image stitching up to 20,000 x 20,000 pixels | ||
+ | * Optical zoom from o to 1000x | ||
+ | * 50 FPS max framerate | ||
- | Insert Text Here! | ||
---- | ---- | ||
- | ===== Operating Procedures | + | ===== Safety Concerns |
+ | * Do not leave lighting elements on | ||
+ | * Do not crash the objectives | ||
+ | * If replacing the bulb in the MI-150 wear gloves to avoid getting oil on the halogen lamp bulb | ||