-=====Detailed Specifications=====+=====About===== 
 +{{:btxelec.jpg?nolink&400|}}
  
 +Scalability, efficiency and versatility are key advantages the system offers researchers. Thanks to the HT-200 High-Throughput Plate Handler, the Gemini X2 can simultaneously place 96 distinct DNA/RNA constructs inside a variety of organisms — and do it in under 20 seconds.
 +
 +Using electrical pulses to create transient gaps in cell walls and move nucleic acids inside, the system can generate both exponential decay and square wave forms, with a wide range of options for voltage and pulse length. As a result, users have the flexibility to work on microbes such as bacteria and yeast, as well as mammalian cells and tissues, in vivo, in vitro and with CRISPR gene-editing experiments.
 +
 +The 96-well plate handler has automated track switching and is compatible with every type of buffer. Importantly, the system matches advanced features with a user-friendly interface on a large color touchscreen. Remote operation is possible with a footswitch or via PC. Internal log storage of experimental data simplifies optimization, quality control and troubleshooting. And safety features include pre-pulse resistance measurement and three layers of arc protection.
 +=====Detailed Specifications=====
  
-* **For Use With (Equipment):** 
-Cuvette Safety Dome, Cuvette Safety Stand, HT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler, BTX Specialty in-Vivo Electrodes\\ 
-Product Line 
-BTX Electroporation 
-Voltage 
-5 to 3000 V 
-Voltage Range (LV Mode) 
-5 to 500 V (in 1 V steps) 
-Display 
-Color Touchscreen 
-Depth (English) 
-13 in. 
-Height (English) 
-8.5 in. 
-Includes 
-Generator, Safety Dome, Cuvettes, Cuvette Rack, Plate Handler, Gap Plates 
-Operating Temperature (English) 
-40°F to 104°F 
-Pulse Length Range 
-Exponential Decay Wave Time constant 0.5 ms to 133.875 ms; Square Wave pulse length 10 ms to 999 ms 
-Relative Humidity 
-80% max. when operating at 25°C 
-Weight (English) 
-16 lb. 
-Width (English) 
-11.25 in. 
-Electrical Requirements 
-100 to 240 VAC 
-Capacitance (HV Mode) 
-85 μF (Square Wave), 10, 25, 35, 50, 60, 75, 85 μF (Exponential Decay Wave) 
-Connection Type 
-Banana Cables 
-Interface 
-Touchscreen 
-High-throughput Compatibility 
-Yes 
  
-3060120 to 300 kV Alignments\\+  **For Use With (Equipment):** Cuvette Safety DomeCuvette Safety StandHT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler, BTX Specialty in-Vivo Electrodes\\ 
 +  * **Product Line:** BTX Electroporation 
 +  * **Voltage:** 5 to 3000 V 
 +  * **Voltage Range (LV Mode):** 5 to 500 V (in 1 V steps) 
 +  * **Display:** Color Touchscreen 
 +  * **Depth (English):** 13 in 
 +  * **Height (English):** 8.5 in 
 +  * **Includes:** Generator, Safety Dome, Cuvettes, Cuvette Rack, Plate Handler, Gap Plates 
 +  * **Operating Temperature (English):** 40°F to 104°F 
 +  * **Pulse Length Range:** Exponential Decay Wave Time constant 0.5 ms to 133.875 ms; Square Wave pulse length 10 ms to 999 ms 
 +  * **Relative Humidity:** 80% max. when operating at 25°C 
 +  * **Weight (English):** 16 lb. 
 +  * **Width (English):** 11.25 in. 
 +  * **Electrical Requirements:** 100 to 240 VAC 
 +  * **Capacitance (HV Mode):** 85 μF (Square Wave), 10, 25, 35, 50, 60, 75, 85 μF (Exponential Decay Wave) 
 +  * **Connection Type:** Banana Cables 
 +  * **Interface:** Touchscreen 
 +  * **High-throughput Compatibility:** Yes 
 +  
lbf-btx.1728417109.txt.gz · Last modified: 2024/10/08 19:51 by okorafor