microed-intro
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
microed-intro [2024/10/02 17:19] – eleni | microed-intro [2024/10/23 17:34] (current) – [About] eleni | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | {{ :image.jpg?800 |}} | + | ====== Micro Electron Diffraction ====== |
+ | |||
+ | ^ Spectra 300C ^ | ||
+ | | {{ :image.jpg?400 |}} | | ||
+ | | **Tool Type: | ||
+ | | **Location: | ||
+ | |||
+ | |||
+ | | **Supervisor** | ||
+ | | Matthew Mecklenburg | ||
+ | | Jungyoun " | ||
+ | |||
+ | | **Description: | ||
+ | | **Manufacturer: | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ===== About ===== | ||
+ | |||
+ | The microED is located in room B117 on the second floor of the CNSI building at the UCLA campus. | ||
MicroED excels at detecting atomic periodicities smaller than 1 Å and ab initio determination of molecular structures at this scale. Better than ~0.8 Å periodicities can be determined in crystals too small to be analyzed using traditional x-ray techniques. MicroED structure solutions reveal all atoms in an assembly, even hydrogens and for semi-crystalline biopolymers, | MicroED excels at detecting atomic periodicities smaller than 1 Å and ab initio determination of molecular structures at this scale. Better than ~0.8 Å periodicities can be determined in crystals too small to be analyzed using traditional x-ray techniques. MicroED structure solutions reveal all atoms in an assembly, even hydrogens and for semi-crystalline biopolymers, | ||
The Spectra 300C is a next-generation high-stability transmission electron microscope. The Spectra’s high brightness X-CFEG field emission gun offers high current in a focused electron probe for 4DSTEM acquisition. This tool is equipped with the latest software and hardware to enable rapid microED data collection at either room temperature or liquid nitrogen temperature. | The Spectra 300C is a next-generation high-stability transmission electron microscope. The Spectra’s high brightness X-CFEG field emission gun offers high current in a focused electron probe for 4DSTEM acquisition. This tool is equipped with the latest software and hardware to enable rapid microED data collection at either room temperature or liquid nitrogen temperature. | ||
+ | ---- | ||
+ | |||
+ | |||
+ | ===== Detailed Specifications ===== | ||
+ | |||
+ | * 30, 60, 120 to 300 kV Alignments\\ | ||
+ | * C-TWIN Lens, Gap = 11 mm, Cs = 2.7 mm\\ | ||
+ | * X-CFEG Cold Field Emission Gun\\ | ||
+ | * Piezo and Motor Driven Computer-controlled Compustage\\ | ||
+ | * +/- 80o single tilt Gatan Elsa Cryo-Transfer holder\\ | ||
+ | * +/- 60/20o dual tilt analytical holder\\ | ||
+ | * +/- 60/20o dual tilt Gatan 915 Cryo-Transfer holder\\ | ||
+ | * STEM, Panther Detector, HAADF, iDPC\\ | ||
+ | * Ceta-D High Speed (4k x 4k, 40 fps)\\ | ||
+ | * 4DSTEM package\\ | ||
+ | * MicroED Package (small beam blocker)\\ | ||
+ | * S/TEM tomography package\\ | ||
+ | * Velox, image analysis software (TFS)\\ | ||
+ | * 5th Generation Octagon with fast kV changes\\ | ||
+ | |||
- | Key features: | ||
- | * 30, 60, 120 to 300 kV Alignments | ||
- | * C-TWIN Lens, Gap = 11 mm, Cs = 2.7 mm | ||
- | * X-CFEG Cold Field Emission Gun | ||
- | * Piezo and Motor Driven Computer-controlled Compustage | ||
- | * +/- 80o single tilt Gatan Elsa Cryo-Transfer holder | ||
- | * +/- 60/20o dual tilt analytical holder | ||
- | * +/- 60/20o dual tilt Gatan 915 Cryo-Transfer holder | ||
- | * STEM, Panther Detector, HAADF, iDPC | ||
- | * Ceta-D High Speed (4k x 4k, 40 fps) | ||
- | * 4DSTEM package | ||
- | * MicroED Package (small beam blocker) | ||
- | * S/TEM tomography package | ||
- | * Velox, image analysis software (TFS) | ||
- | * 5th Generation Octagon with fast kV changes |
microed-intro.1727889557.txt.gz · Last modified: 2024/10/02 17:19 by eleni