NSF BioPACIFIC MIP Wiki

A National User Facility Dedicated to Biomaterials

User Tools

Site Tools


microed-intro

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
microed-intro [2024/10/02 17:30] elenimicroed-intro [2024/10/23 17:34] (current) – [About] eleni
Line 3: Line 3:
 ^                  Spectra 300C                       ^ ^                  Spectra 300C                       ^
 |             {{ :image.jpg?400 |}}                                                 |             {{ :image.jpg?400 |}}                                                
-| **Tool Type:**                  ""                           |+| **Tool Type:**                  "Spectra 300C                          |
 | **Location:**                   "CNSI"                           | | **Location:**                   "CNSI"                           |
  
Line 18: Line 18:
 ===== About ===== ===== About =====
  
-The microED is located in room xxxx on the second floor of the CNSI building at the UCLA campus. +The microED is located in room B117 on the second floor of the CNSI building at the UCLA campus. 
  
 MicroED excels at detecting atomic periodicities smaller than 1 Å and ab initio determination of molecular structures at this scale. Better than ~0.8 Å periodicities can be determined in crystals too small to be analyzed using traditional x-ray techniques. MicroED structure solutions reveal all atoms in an assembly, even hydrogens and for semi-crystalline biopolymers, and regions of local order/disorder are revealed. Importantly, in the best of cases, these structures can be rapidly determined (within 1h) from powders. Thus, the promising materials generated from the foundry (both small molecules and polymers) can rapidly be characterized by this novel electron diffraction technique. MicroED excels at detecting atomic periodicities smaller than 1 Å and ab initio determination of molecular structures at this scale. Better than ~0.8 Å periodicities can be determined in crystals too small to be analyzed using traditional x-ray techniques. MicroED structure solutions reveal all atoms in an assembly, even hydrogens and for semi-crystalline biopolymers, and regions of local order/disorder are revealed. Importantly, in the best of cases, these structures can be rapidly determined (within 1h) from powders. Thus, the promising materials generated from the foundry (both small molecules and polymers) can rapidly be characterized by this novel electron diffraction technique.
Line 28: Line 28:
 ===== Detailed Specifications ===== ===== Detailed Specifications =====
  
-**30, 60, 120 to 300 kV Alignments**\\ +  * 30, 60, 120 to 300 kV Alignments\\ 
-**C-TWIN Lens, Gap = 11 mm, Cs = 2.7 mm**\\ +  * C-TWIN Lens, Gap = 11 mm, Cs = 2.7 mm\\ 
-**X-CFEG Cold Field Emission Gun**\\ +  * X-CFEG Cold Field Emission Gun\\ 
-**Piezo and Motor Driven Computer-controlled Compustage**\\ +  * Piezo and Motor Driven Computer-controlled Compustage\\ 
-**+/- 80o single tilt Gatan Elsa Cryo-Transfer holder**\\ +  * +/- 80o single tilt Gatan Elsa Cryo-Transfer holder\\ 
-**+/- 60/20o dual tilt analytical holder**\\ +  * +/- 60/20o dual tilt analytical holder\\ 
-**+/- 60/20o dual tilt Gatan 915 Cryo-Transfer holder**\\ +  * +/- 60/20o dual tilt Gatan 915 Cryo-Transfer holder\\ 
-**STEM, Panther Detector, HAADF, iDPC**\\ +  * STEM, Panther Detector, HAADF, iDPC\\ 
-**Ceta-D High Speed (4k x 4k, 40 fps)**\\ +  * Ceta-D High Speed (4k x 4k, 40 fps)\\ 
-**4DSTEM package**\\ +  * 4DSTEM package\\ 
-**MicroED Package (small beam blocker)**\\ +  * MicroED Package (small beam blocker)\\ 
-**S/TEM tomography package**\\ +  * S/TEM tomography package\\ 
-**Velox, image analysis software (TFS)**\\ +  * Velox, image analysis software (TFS)\\ 
-**5th Generation Octagon with fast kV changes**\\ +  * 5th Generation Octagon with fast kV changes\\ 
-----+
  
  
microed-intro.1727890231.txt.gz · Last modified: 2024/10/02 17:30 by eleni