rs232_file_transfer_documentation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

rs232_file_transfer_documentation [2021/03/10 18:29] – created furstrs232_file_transfer_documentation [2021/03/10 18:32] (current) – [Troubleshooting/setup check] furst
Line 16: Line 16:
   - Insure that the DNC settings on the Haas match those selected under "machine 1" on the Haas computer. Keep in mind a different value of baud rate or start/stop codes will cause problems when sending files.   - Insure that the DNC settings on the Haas match those selected under "machine 1" on the Haas computer. Keep in mind a different value of baud rate or start/stop codes will cause problems when sending files.
  
 +  * Faster Baud rates will result in faster file transfer, however it also greatly increases the chances of errors or failure during transmission. Haas recommends a Baud rate of 9600 with a maximum baud rate of 115.2 kbaud.
rs232_file_transfer_documentation.1615400981.txt.gz · Last modified: 2021/03/10 18:29 by furst