NSF BioPACIFIC MIP Wiki

A National User Facility Dedicated to Biomaterials

User Tools

Site Tools


shimadzu_nexera_analytical_hplc

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
shimadzu_nexera_analytical_hplc [2024/10/16 19:48] – created mbatesshimadzu_nexera_analytical_hplc [2024/10/16 20:13] (current) – [Manufacturer Hardware Manuals] mbates
Line 15: Line 15:
 ===== About ===== ===== About =====
  
-The Genevac EZ-2 4.0 Elite is high-performance parallel evaporator system designed to efficiently remove solvents from samples through evaporationIt uses advanced vacuum and centrifugal technology to evaporate wide range of solventsincluding volatile organic compounds and aqueous solutions, without overheating or degrading sensitive samples. The EZ-2 Elite features a dry scroll pump and is optimized for removal of even the highest boiling point solvents (> 165 °C), such as DMSO and NMP.+The Shimadzu Nexera Analytical HPLC system enables the identification and quantification of complex mixtures, while also supporting method development for sample purification on both preparative and semi-preparative scalesEquipped with 6-way switch valve, the system streamlines the selection between four distinct columns, each offering unique surface chemistry and retention propertiesThese include C18 columns with 100 and 300 Å pore sizes, C4 column, and a HILIC column. The system's design also allows for easy eluent interchanges, ensuring flexible adaptation to various purification and characterization requirements. Additionally, it features a dedicated PDA and a single quad LCMS-2050 mass spectrometer, which is capable of both ESI and APCI ionization and covers a mass range of 10-2000 m/z.
  
 ---- ----
  
  
-===== Solvent Guidelines and Sample Holder Options =====+===== Reference Documentation =====
  
-**Solvent Compatibility** \\ +{{ :analytical_hplc_manual.pdf | NSF BioPACIFIC MIP Analytical HPLC-MS User Manual}}
- +
-SP Genevac evaporators are robust systems designed to be resistant to the most common solvents and acids used within the chemistry laboratory, including TFA and HCl**However, the Genevac is not compatible with the following:**\\ +
- +
-• Carbon disulfide\\ +
-• Diethyl ether\\ +
-• 1,2-Dimethoxyethane\\ +
-• 2-Ethoxyethanol\\ +
-• Hydrogen cyanide\\ +
-• Pentane\\ +
-• Triethylsilane\\ +
- +
-**Sample formats** +
- +
-Sample holders for the following formats are available:\\ +
- +
-• **Vials:** 40, 30, 20, and 8-mL sizes \\ +
-• **Test tubes:** 16, 18, and 25-mm diameter and up to 150 mm length \\ +
-• **Centrifuge tubes:** 50-mL size+
  
 ---- ----
- 
- 
  
  
shimadzu_nexera_analytical_hplc.1729108123.txt.gz · Last modified: 2024/10/16 19:48 by mbates