ultimaker3_extended [2020/08/18 17:42] – [Safety Concerns] furstultimaker3_extended [2020/11/04 01:06] (current) – [Detailed Specifications] dave
Line 25: Line 25:
 =====Training===== =====Training=====
 [[Ultimaker 3 SOP|FDM Printer SOP]]\\ [[Ultimaker 3 SOP|FDM Printer SOP]]\\
-[[Ultimaker 3 Quick Review]]+ 
 ----- -----
  
 ===== Detailed Specifications ===== ===== Detailed Specifications =====
  
-Build Volume: 215 x 215 x 300 mm \\  +  *Build Volume: 215 x 215 x 300 mm \\  
-Filament diameter: 2.85 mm\\  +  *Filament diameter: 2.85 mm\\  
-layer resolution: 60 to 600 microns depending on print head (see Specifications documentation  page 11)\\  +  *layer resolution: 60 to 600 microns depending on print head (see Specifications documentation  page 11)\\  
-XYZ accuracy: 12.5, 12.5, 2.5 microns \\  +  *XYZ accuracy: 12.5, 12.5, 2.5 microns \\  
-Build plate temperature: 20-100 °C\\  +  *Build plate temperature: 20-100 °C\\  
-Nozzle temperature: 80 - 100 °C\\  +  *Nozzle temperature: up to 210 °C\\  
-----+ 
 +----
  
  
Line 43: Line 46:
   * The print heads can be very hot - do not touch them with bare hands unless positive they are cool.   * The print heads can be very hot - do not touch them with bare hands unless positive they are cool.
   * As with any automated machinery make sure that your body is clear of the moving parts to avoid injury.   * As with any automated machinery make sure that your body is clear of the moving parts to avoid injury.
-  * The support removal tank for the F270 is filled with heated caustic chemicals that dissolve the support material. An apron, Gloves, and a face shield must be warn when inserting and removing parts or basket from tank.+  * The support removal tank for the F270 is filled with heated caustic chemicals that dissolve the support material. An apron, Gloves, and a face shield must be warn when inserting and removing parts or basket from the  tank.
  
 ---- ----
Line 65: Line 68:
 [[https://support.ultimaker.com/hc/en-us/articles/360012007119]]\\ [[https://support.ultimaker.com/hc/en-us/articles/360012007119]]\\
 {{:tools:ultimaker3:pva_drying_recipe.pdf|}}\\ {{:tools:ultimaker3:pva_drying_recipe.pdf|}}\\
-{{:tools:ultimaker3:ultimaker_filaments_-_sheet1.pdf|}}+{{:tools:ultimaker3:ultimaker_filaments_-_sheet1.pdf|}} \\
 {{:tools:ultimaker3:failed_3d_print_procedure.pdf|}} {{:tools:ultimaker3:failed_3d_print_procedure.pdf|}}
 +
 +-----
  
  
  