-The Genevac EZ-2 4.0 Elite is a high-performance evaporator system designed to efficiently remove solvents from samples through evaporation. It uses advanced vacuum and centrifugal technology to evaporate a wide range of solvents, including volatile organic compounds and aqueous solutions, without overheating or degrading sensitive samples. The EZ-2 Elite features a dry scroll pump and is optimized for removal of even the highest boiling point solvents (> 165 C), such as DMSO and NMP.+The Genevac EZ-2 4.0 Elite is a high-performance parallel evaporator system designed to efficiently remove solvents from samples through evaporation. It uses advanced vacuum and centrifugal technology to evaporate a wide range of solvents, including volatile organic compounds and aqueous solutions, without overheating or degrading sensitive samples. The EZ-2 Elite features a dry scroll pump and is optimized for removal of even the highest boiling point solvents (> 165 °C), such as DMSO and NMP.
  
 ---- ----
  
  
-===== Detailed Specifications =====+===== Solvent Guidelines and Sample Holder Options =====
  
-**Solvent Compatibility:** \\+**Solvent Compatibility** \\
  
 SP Genevac evaporators are robust systems designed to be resistant to the most common solvents and acids used within the chemistry laboratory, including TFA and HCl. **However, the Genevac is not compatible with the following:**\\ SP Genevac evaporators are robust systems designed to be resistant to the most common solvents and acids used within the chemistry laboratory, including TFA and HCl. **However, the Genevac is not compatible with the following:**\\
Line 34: Line 34:
 • Triethylsilane\\ • Triethylsilane\\
  
-**Sample holders for the following formats are available:**\\+**Sample formats**
  
-• 40-, 30-, 20-, and 8-mL vials \\ +Sample holders for the following formats are available:\\ 
-• 16-, 18-, and 25-mm diameter and 150 mm length test tubes \\ + 
-• 50-mL centrifuge tubes+• **Vials:** 40, 30, 20, and 8-mL sizes \\ 
 +• **Test tubes:** 16, 18, and 25-mm diameter and up to 150 mm length \\ 
 +• **Centrifuge tubes:** 50-mL size
  
 ---- ----
- 
  
 ===== Reference Documentation ===== ===== Reference Documentation =====
  
-{{ :biotagev10touchmanual.pdf |V-10 User Manual}} +{{ :EZ2Manual.pdf | Installation and Maintenance Manual}}
  
 ----- -----
genevac_ez2_4.0_benchtop_evaporator.1728945887.txt.gz · Last modified: 2024/10/14 22:44 by mbates