NSF BioPACIFIC MIP Wiki

A National User Facility Dedicated to Biomaterials

User Tools

Site Tools


genevac_ez2_4.0_benchtop_evaporator

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
genevac_ez2_4.0_benchtop_evaporator [2024/10/15 00:35] – [Detailed Specifications] mbatesgenevac_ez2_4.0_benchtop_evaporator [2024/10/21 18:20] (current) mbates
Line 15: Line 15:
 ===== About ===== ===== About =====
  
-The Genevac EZ-2 4.0 Elite is a high-performance evaporator system designed to efficiently remove solvents from samples through evaporation. It uses advanced vacuum and centrifugal technology to evaporate a wide range of solvents, including volatile organic compounds and aqueous solutions, without overheating or degrading sensitive samples. The EZ-2 Elite features a dry scroll pump and is optimized for removal of even the highest boiling point solvents (> 165 °C), such as DMSO and NMP.+The Genevac EZ-2 4.0 Elite is a high-performance parallel evaporator system designed to efficiently remove solvents from samples through evaporation. It uses advanced vacuum and centrifugal technology to evaporate a wide range of solvents, including volatile organic compounds and aqueous solutions, without overheating or degrading sensitive samples. The EZ-2 Elite features a dry scroll pump and is optimized for removal of even the highest boiling point solvents (> 165 °C), such as DMSO and NMP.
  
 ---- ----
Line 22: Line 22:
 ===== Solvent Guidelines and Sample Holder Options ===== ===== Solvent Guidelines and Sample Holder Options =====
  
-**Solvent Compatibility:** \\+**Solvent Compatibility** \\
  
 SP Genevac evaporators are robust systems designed to be resistant to the most common solvents and acids used within the chemistry laboratory, including TFA and HCl. **However, the Genevac is not compatible with the following:**\\ SP Genevac evaporators are robust systems designed to be resistant to the most common solvents and acids used within the chemistry laboratory, including TFA and HCl. **However, the Genevac is not compatible with the following:**\\
Line 33: Line 33:
 • Pentane\\ • Pentane\\
 • Triethylsilane\\ • Triethylsilane\\
 +
 +**Sample formats**
  
 Sample holders for the following formats are available:\\ Sample holders for the following formats are available:\\
Line 42: Line 44:
 ---- ----
  
 +===== Reference Documentation =====
  
 +{{ :EZ2Manual.pdf | Installation and Maintenance Manual}}
  
 +-----
  
  
genevac_ez2_4.0_benchtop_evaporator.1728952523.txt.gz · Last modified: 2024/10/15 00:35 by mbates